YCX8-IF Solar DC Fuse Box
Features ● IP65; ● 3ms arc suppression; ● Lockable in closed position; ● Fuses with overcurrent protection. Technical data Model YCX8-IF III 32/32 Input/Output III Maximum voltage 1000VDC Maximum DC short-circuit current per input (Isc) 15A(Adjustable) Maximum output current 32A Shell frame Material Polycarbonate/ABS Protection degree IP65 Impact resistance IK10 Dimension(width ×height ×depth) 381*230*110 Configuration (recommended) Photovoltaic isolation switch YCISC...
YCF8-H High Current Photovoltaic DC Fuse
Selection Link YCF8 — H00 100A DC1000V Model Size Rated current Rated voltage Fuse H00 16-100A DC1000V H1 32-160A H2 160-250A H3 250-400A H1XL 35-200A DC1500 H2XL 80-400A H3L 125-500A Base YCF8 — H00B Model Size Fuse H00B H1B H2B H3B H1XLB H2XLB H3LB Technical data Model Fuse specifications YCF8-H00 YCF8-H1 YCF8-H2 YCF8-H3 YCF8-H1XL YCF8-H2XL YCF8-H3L Breaking capacity (kA) 50kA 30kA Time constant (ms) 1-3ms 1-3ms Specification of fuse ho...
YCX8-BS Over-Load Protection Box
Features ● IP66; ● 1 input 4 output, 600VDC/1000VDC; ● Lockable in closed position; ● UL 508i certificated, Standard: IEC 60947-3 PV2. Technical data Model YCX8-BS 1/1 YCX8-BS 6/2 Input/Output 1/1, 3/1 6/2 Maximum voltage 1000VDC Maximum output current 1~63A/63A~125A Shell frame Material Polycarbonate/ABS Protection degree IP65 Impact resistance IK10 Dimension(width ×height ×depth) 219*200*100mm 381*230*110 Configuration (recommended) Photovoltaic DC circuit breake YCB8...
YCX8-DIS Door Clutch Combiner
Features ● IP66; ● 1 input 4 output, 600VDC/1000VDC; ● Lockable in closed position; ● UL 508i certificated, Standard: IEC 60947-3 PV2. Technical data Model YCX8-DIS 1/1 15/32 Input/Output 1/1 Maximum voltage 600V 1000V Short circuit current per input (Isc) 15A-30A(Adjustable) Maximum output current 16A 25A Shell frame Material Polycarbonate Protection degree IP66 Impact resistance IK10 Dimension(width ×height ×depth) 160*210*110 Input cable gland MC4/PG09,2.5~16mm Out...
PV Photovoltaic DC Cable
Features Cable Full Name: Halogen-free low smoke cross-linked polyolefin insulated and sheathed cables for photovoltaic power generation systems. Conductor Structure: En60228 (IEC60228) Type five conductor and must be tinned copper wire. Cable Color: Black or Red (The insulation material shall be extruded halogen-free material, which shall be composed of one layer or several tightly adhered layers. The insulation shall be solid and uniform in material, and the insulation itself, the conducto...
YCB1-125 MCB
Curve Specifications Type Standard IEC/EN 60947-2 IEC/EN 60898-1 Electrical features Rated current In A 63, 80, 100, 125 Poles P 1, 2, 3, 4 Rated voltage Ue V 230/400 Insulation voltage Ui V 500 Rated frequency Hz 50/60 Rated breaking capacity A 6000 Rated impulse withstand voltage(1.2/50) Uimp V 6000 Dielectric test voltage at ind. Freq. for 1min kV 2.5 Pollution degree 3 Thermo-magnetic release characteristic 8-12In B, C,D Mechanical features Electrical life t ...